<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Articles on FormuLens</title><link>https://www.formulens.com/articles/</link><description>Recent content in Articles on FormuLens</description><generator>Hugo</generator><language>en-us</language><lastBuildDate>Tue, 02 Jan 2024 09:07:34 +0000</lastBuildDate><atom:link href="https://www.formulens.com/articles/index.xml" rel="self" type="application/rss+xml"/><item><title>Lens design publication</title><link>https://www.formulens.com/articles/lens-design-publication/</link><pubDate>Mon, 02 Oct 2023 09:02:21 +0000</pubDate><guid>https://www.formulens.com/articles/lens-design-publication/</guid><description>&lt;p&gt;We presented a paper describing some of the core ideas behind our lens design algorithm in San Diego at the SPIE Current Developments in Lens Design and Optical Engineering.&lt;/p&gt;&#10;&lt;p&gt;Link to paper as well as video of presentation: &lt;a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/12666/1266604/Optimization-of-freeform-spectacle-lenses-based-on-high-order-aberrations/10.1117/12.2676950.short"&gt;Optimization of freeform spectacle lenses based on high-order aberrations&lt;/a&gt; (&lt;a href="https://www.keithdillon.com/papers_preprints/Optimization%20of%20freeform%20spectacle%20lenses%20based%20on%20high-order%20aberrations.pdf"&gt;pdf&lt;/a&gt;)&lt;/p&gt;</description></item><item><title>FormuLens Ops</title><link>https://www.formulens.com/articles/enterprise-operations/</link><pubDate>Sun, 14 May 2023 23:03:05 +0000</pubDate><guid>https://www.formulens.com/articles/enterprise-operations/</guid><description>&lt;p&gt;FormuLens Enterprise Operations (FormuLens Ops) is a cloud-based system of tools for giving businesses direct control over multiple lens designs and manufacturing labs. With FormuLens Ops, businesses may configure the LDS (lens design software) options available to a lab or ECP by adding and removing available lens design options, adjusting and renaming those lens design options, and viewing production information and individual job performance. Businesses may add accounts for labs or ECPs, as well as view and configure the manufacture settings used by each.&lt;/p&gt;</description></item><item><title>LifeForm Progressive Design</title><link>https://www.formulens.com/articles/lifeform-progressive-design/</link><pubDate>Thu, 21 Jan 2021 18:03:35 +0000</pubDate><guid>https://www.formulens.com/articles/lifeform-progressive-design/</guid><description>&lt;p&gt;&lt;em&gt;Lenses individually tailored to lifestyle&lt;/em&gt;&lt;/p&gt;&#10;&lt;p&gt;Our LifeForm progressive addition lens design can be viewed as a set of 14 different designs which target different usage priorities (including balanced options, for general use), while still providing full progressive functionality. The ideal lens can be selected in seconds using a simple 3-question survey which is summarized in the table below (further detail after the table).&lt;/p&gt;&#10;&lt;p&gt;Alternatively, a practitioner who wishes to limit offerings to a small set of options can use the table to select those options.&lt;/p&gt;</description></item><item><title>SimuLens base functions</title><link>https://www.formulens.com/articles/simulens-base-functions/</link><pubDate>Tue, 13 Oct 2020 19:50:34 +0000</pubDate><guid>https://www.formulens.com/articles/simulens-base-functions/</guid><description>&lt;p&gt;We have a new webpage explaining the basic functionality in SimuLens for simulating lenses in a variety of ways.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.formulens.com/notebooks/images/simulens_fitting_3D.png" alt="gazing through a lens&amp;hellip;"&gt;&lt;/p&gt;&#10;&lt;p&gt;&lt;a href="https://www.formulens.com/notebooks/SimuLensDemo01.html"&gt;Click here to check it out.&lt;/a&gt;&lt;/p&gt;</description></item><item><title>Aspheric Back Surface Designs</title><link>https://www.formulens.com/articles/aspheric-back-surface-designs/</link><pubDate>Sat, 08 Dec 2018 15:20:51 +0000</pubDate><guid>https://www.formulens.com/articles/aspheric-back-surface-designs/</guid><description>&lt;p&gt;For high power single-vision lenses, significant improvement can be achieved with freeform lenses, even with spheric blanks. The following plots describe the performance for a surface optimized for a +13 Diopter prescription with CR-39 and  a spheric blank.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.formulens.com/images/2020/09/godesign03_sim13p5.png" alt=""&gt;&lt;/p&gt;&#10;&lt;p&gt;As the first plot shows, the aspheric back surface is most strongly curved for a plus lens, resulting in a thinner design.&lt;/p&gt;&#10;&lt;p&gt;The next two plots show the improvement in both sphere and cylinder error across the gaze angles. The constant spherical equivalent means there is a constant magnification and hence the image is not distorted.&lt;/p&gt;</description></item><item><title>Small Lab LDS Software</title><link>https://www.formulens.com/articles/small-lab-lds-software/</link><pubDate>Tue, 16 May 2017 00:13:08 +0000</pubDate><guid>https://www.formulens.com/articles/small-lab-lds-software/</guid><description>&lt;p&gt;FormuLens provides a minimal but fully-functional Lens Design Software (LDS) interface for ECPs with their own generator and small labs, who don’t wish to purchase an expensive Lab Management System (LMS).&lt;/p&gt;&#10;&lt;p&gt;The Rx entry form can be used either from a webpage (which can also be provided to ECPs to enter orders) or directly from the Lab in a stand-alone application called &lt;em&gt;FormuLab&lt;/em&gt;:&lt;br&gt;&#10;&lt;img src="https://www.formulens.com/images/2017/05/custom_generic_form.jpg" alt=""&gt;&lt;/p&gt;&#10;&lt;p&gt; &lt;/p&gt;&#10;&lt;p&gt;&lt;em&gt;FormuLab&lt;/em&gt; also provides the ability to save and reload/remake jobs from our server, including full access to previously-used settings.&lt;/p&gt;</description></item><item><title>Higher-order wavefront correction</title><link>https://www.formulens.com/articles/higher-order-wavefront-correction/</link><pubDate>Sun, 14 May 2017 07:44:17 +0000</pubDate><guid>https://www.formulens.com/articles/higher-order-wavefront-correction/</guid><description>&lt;p&gt;With completely custom lens surfaces comes the opportunity to try and address higher order aberrations. The changing gaze angle of the eye during normal vision makes correction difficult in general use. However, researchers have claimed some improvements in vision using aspheric designs. Further, vision is a very active process, wherein eye movements  are undertaken to improve understanding of the current scene. This suggests that the eye might discover and utilize a special high-order correction zone.&lt;/p&gt;</description></item><item><title>Progressive Addition Lens Anatomy</title><link>https://www.formulens.com/articles/progressive-lens-anatomy/</link><pubDate>Tue, 13 Dec 2016 11:44:08 +0000</pubDate><guid>https://www.formulens.com/articles/progressive-lens-anatomy/</guid><description>&lt;p&gt;With digital lens surfacing (a.k.a. freeform) one or both surfaces of a lens can be completely specified by the Lens Design System (LDS). For example the LDS can provide a &lt;em&gt;height map&lt;/em&gt;, giving points on a grid of some chosen spacing. This surface will be produced with very high accuracy by the generator.&lt;/p&gt;&#10;&lt;p&gt;The optical performance of a freeform lens when used in spectacles is difficult to predict. Either the lens must be manufactured and analyzed with a complex apparatus that can measure optical properties for a range of realistic view directions, or the lens must be simulated computationally using sophisticated ray-tracing algorithms.&lt;/p&gt;</description></item><item><title>Fast &amp; Robust Wavefront Sensing</title><link>https://www.formulens.com/articles/fast-robust-wavefront-sensing/</link><pubDate>Wed, 07 Dec 2016 00:47:02 +0000</pubDate><guid>https://www.formulens.com/articles/fast-robust-wavefront-sensing/</guid><description>&lt;p&gt;Rapidly rising levels of myopia, particularly in the developing world, have led to an increased need for inexpensive and automated approaches to optometry. A simple and robust technique is provided for estimating major ophthalmic aberrations using a gradient-based wavefront sensor. The approach is based on the use of numerical calculations to produce diverse combinations of phase components, followed by Fourier transforms to calculate the coefficients. The approach does not utilize phase unwrapping nor iterative solution of inverse problems. This makes the method very fast and tolerant to image artifacts, which do not need to be detected and masked or interpolated as is needed in other techniques. These features make it a promising algorithm on which to base low-cost devices for applications that may have limited access to expert maintenance and operation.&lt;/p&gt;</description></item><item><title>Custom Generic Progressive Lens</title><link>https://www.formulens.com/articles/custom-generic/</link><pubDate>Thu, 01 Jan 2015 12:24:20 +0000</pubDate><guid>https://www.formulens.com/articles/custom-generic/</guid><description>&lt;p&gt;The FormuLens &lt;em&gt;Custom Generic&lt;/em&gt; PAL (Progressive Addition Lens) is a single product which can be adjusted through a wide range of performance requirements. It offers adjustable fitting heights from 12 to 22 mm, and “hardness” ranging between the extremes offered by designs from major vendors, and everything in between. The design is optimized computationally using our lens design system &lt;a href="https://www.formulens.com/articles/simpal/"&gt;SimPAL&lt;/a&gt; for a dense grid of setting combinations.&lt;/p&gt;&#10;&lt;p&gt;Direct inputs can be made to choose desired Custom Generic settings using our &lt;a href="https://www.formulens.com/articles/small-lab-lds-software/"&gt;Small Lab LDS Software&lt;/a&gt;, as in the following screenshot:&lt;/p&gt;</description></item><item><title>SimPAL</title><link>https://www.formulens.com/articles/simpal/</link><pubDate>Sat, 25 Feb 2012 00:11:50 +0000</pubDate><guid>https://www.formulens.com/articles/simpal/</guid><description>&lt;p&gt;Progressive Lens design is a complex problem. As described in our  &lt;a href="https://www.formulens.com/articles/progressive-lens-anatomy/"&gt;PAL Anatomy&lt;/a&gt;  article, there are a large number of lens details to optimize and trade-off. Further, it is not even clear how one can change such structural features to get the desired result.&lt;/p&gt;&#10;&lt;p&gt;The typical approach to lens design is depicted below. The lens designer controls a lens generator of some kind, which provides the ability to produce a range of variations of a lens. When a lens is produced, it is analyzed and tested, and the results are used to adjust the inputs in order to hopefully generate a better lens. Typically a large number of adjustments and settings are preset to fixed values to make the problem manageable.&lt;/p&gt;</description></item><item><title>SimuLens</title><link>https://www.formulens.com/articles/simulens/</link><pubDate>Sun, 19 Sep 2010 00:08:22 +0000</pubDate><guid>https://www.formulens.com/articles/simulens/</guid><description>&lt;p&gt;SimuLens performs a realistic simulation of a spectacle lens in use. The lens is to be described by arbitrary sets of points describing the front and back surfaces (e.g. generator points-files), and a refractive index. The eye position relative to the points is computed based on fitting parameters.&lt;/p&gt;&#10;&lt;p&gt;&lt;img src="https://www.formulens.com/images/2017/05/2D_eye_spec_plus.png" alt=""&gt;&lt;/p&gt;&#10;&lt;p&gt;The more complete and accurate the information describing position is, the more accurate the estimate of visual performance will be. Ideally a complete set of fitting parameters should be collected.&lt;/p&gt;</description></item><item><title>Zernike Polynomials</title><link>https://www.formulens.com/articles/zernike-polynomials/</link><pubDate>Wed, 29 Jul 2009 00:38:06 +0000</pubDate><guid>https://www.formulens.com/articles/zernike-polynomials/</guid><description>&lt;p&gt;Truncated expansions such as Zernike polynomials provide a powerful approach for describing wavefront data. However, many simple calculations with data in this form can require significant computational effort. Important examples include recentering, renormalizing, and translating the wavefront data. This paper describes a technique whereby these operations and many others can be performed with a simple matrix approach using monomials. The technique may be applied to other expansions by reordering the data and applying transformations. The key is the use of the vectorization operator to convert data between vector and matrix descriptions. With this conversion, one-dimensional polynomial techniques may be employed to perform separable operations. Examples are also given for differentiation and integration of wavefronts.&lt;/p&gt;</description></item></channel></rss>